Seitenansicht 60
Unit Object Commands
www.3ware.com 55
/c
x
/u
x
show rebuildstatus
This command reports the rebuildstatus (if any) of the specified unit.
Example:
//localhost> /c0/u5 show rebuildstatus
/c0/u5 is not rebuilding, its current state is OK
If the unit is in the process of migrating, the command will return the
following:
//localhost> /c0/u5 show rebuildstatus
/c0/u5 is not rebuilding, its current state is MIGRATING
/c
x
/u
x
show verifystatus
This command reports the verifystatus (if any) of the specified unit.
Example:
//localhost> /c0/u5 show verifystatus
/c0/u5 is not verifying, its current state is OK
/c
x
/u
x
show initializestatus
This command reports the initializestatus (if any) of the specified unit.
Example:
//localhost> /c0/u5 show initializestatus
/c0/u5 is not initializing, its current state is OK
/c
x
/u
x
show name
This feature only applies to 9000 series controllers.
This command reports the name (if any) of the specified unit.
Example:
//localhost> /c0/u5 show name
/c0/u5 name = Joe
/c
x
/u
x
show serial
This feature only applies to 9000 series controllers.
This command reports the unique serial number of the specified unit.
Example:
//localhost> /c0/u5 show serial
/c0/u5 Serial Number = 12345678901234567890