AMCC 3WARE 9500S Betriebsanweisung Seite 117

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 302
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 116
Setting Unit Policies
www.3ware.com 107
Continue on Source Error During Rebuild. Determines whether ECC
errors are ignored when they are encountered during a rebuild. (ECC
errors are an indication of errors that have occurred on a particular drive
since it was last read.) When not enabled, a rebuild will abort upon
encountering an ECC error and the unit will be set to Degraded. For
details, see “Setting Continue on Source Error During Rebuild” on
page 110.
Queuing. Determines whether NCQ (Native Command Queuing) is
enabled for the unit. When enabled for drives that support it, this policy
can improve performance. For details, see “Enabling and Disabling
Queuing for a Unit” on page 111.
StorSave Profile. Determines what StorSave profile is used for the unit.
Three profiles are available: Protection, Balanced, and Performance. For
details, see “Setting the StorSave Profile for a Unit” on page 112.
Figure 52. Unit Policies on Controller Settings Page in 3DM
Seitenansicht 116
1 2 ... 112 113 114 115 116 117 118 119 120 121 122 ... 301 302

Kommentare zu diesen Handbüchern

Keine Kommentare