AMCC 3WARE 9500S Betriebsanweisung Seite 242

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 302
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 241
Chapter 12. Troubleshooting
232 3ware Serial ATA RAID Controller User Guide
See Also
For links to drive manufacturer diagnostic utilities and troubleshooting
advice, see
http://www.3ware.com/KB/article.aspx?id=14924.
“Basic Troubleshooting: Check This First” on page 219
000A Drive error detected
Event Type
Error
Cause
A drive has returned an error to the 3ware RAID controller that it is unable to
complete a command. The error type is not a time-out (000A) or uncorrected
ECC (0026).
This message may be seen as part of a recovery operation initiated by the
3ware RAID controller on the drive. One possible cause is multiple write
commands to a sector forcing the drive to remap a defective sector. This
message may be seen if error recovery operations initiated by the 3ware
RAID controller are unsuccessful.
Action
If you see this message, the drive repairs may lie outside of the 3ware RAID
controllers abilities.Try running the drive manufacturers diagnostic and
repair utilities on the drive.
If necessary, replace the drive.
See Also
For links to drive manufacturer diagnostic utilities and troubleshooting
advice, see
http://www.3ware.com/KB/article.aspx?id=10894.
000B Rebuild started
Event Type
Information
Cause
The 3ware RAID controller started to rebuild a degraded unit. The rebuild
may have been initiated by you, may have started automatically on a hot spare
or may have started after drive removal or insertion (due to the Auto Rebuild
policy).
Seitenansicht 241