
Error and Notification Messages
www.3ware.com 257
004C Battery temperature is too low
Event Type
Error
Cause
The battery pack temperature being monitored by the Battery Backup Unit is
too low.
The BBU is unable to backup the 3ware RAID controller.
Action
Contact 3ware technical support at
http://www.3ware.com/support/index.asp.
The battery pack must be replaced if the problem persists and is not due to
environmental reasons.
004D Battery temperature is too high
Event Type
Error
Cause
The battery pack temperature being monitored by the Battery Backup Unit is
too high.
The BBU is unable to backup the 3ware RAID controller.
Action
Check for sufficient airflow around the card. To increase airflow you can:
• Leave the PCI slots next to the controller empty
• Add fans to your computer case
• Move and bundle wiring that is blocking air circulation
Contact 3ware technical support at
http://www.3ware.com/support/index.asp
if this problem is not due to environmental reasons or improper case cooling.
004E Battery capacity test started
Event Type
Information
Cause
A battery test was started through CLI or 3DM.
Kommentare zu diesen Handbüchern