Seitenansicht 101
Chapter 2. CLI Syntax Reference
96 3ware Serial ATA RAID Controller User Guide
/cx/ex/fan
x
set identify=on|off
This command is used by 9690SA controllers.
This command causes the fan to be identified by blinking the LED associated
with it, or turns off identification of the LED for this fan.
Setting identify to on will cause the LED associated with that fan to blink.
Example:
//localhost> c0/e0/fan1 set identify=on
Sending Identify request to Fan c0/e0/fan1 to [on] ... Done.
/c
x
/e
x
/pwrs
x
show
This command is used by the 9690SA controller.
This command shows the information about the specified power supply
element /pwrsx in the specified enclosure cx/ex. The power supply name is
followed by its status. The possible status values are OK, OVERTEMP-
FAILURE, OVERTEMP-WARNING, DC-FAIL. and AC-FAIL. The possible
Voltage and Current values are OK, OVER-WARNING, and UNDER-
WA RN ING.
If a power supply is on and no fault has been detected, the status would
indicate OK.
/cx/ex/pwrs
x
show identify
This command is used by 9690SA controllers.
This command shows the identify status of the specified power supply The
status can be either on or off.
Example:
//localhost> c0/e0/pwrs1 show identify
c0/e0/pwrs1 Identify status = on