Chapter 2. CLI Syntax Reference
72 3ware Serial ATA RAID Controller User Guide
/c
x
/u
x
set qpolicy=on|off
This feature only applies to 9000 series SX/SE/SA model controllers.
This command sets the queue policy of the firmware. If the queue policy is
on, the firmware utilizes the drive’s queueing policy. If any drives do not
support a queueing policy, this policy will have no effect on those drives.
For a spare unit, drive queuing is not meaningful or applicable. When a spare
becomes part of a true unit during a rebuild, it adopts the queue policy of the
''new'' parent unit. Thus, this command does not set the queue policy for the
spare unit type.
Note: Queing is only applicable for SATA drives.
By default, qpolicy is
on.
Example:
//localhost> /c0/u5 set qpolicy = on
Setting Command Queuing Policy for unit /c0/u5 to [on] ... Done.
/c
x
/u
x
set storsave=protect|balance|perform [quiet]
This feature only applies to 9000 series SX/SE/SA model controllers.
This command sets the storsave policy to be either protect, balance, or
perform when the unit write cache is enabled. The default setting is protect.
The storsave policy adjusts several factors that control the balance between
protection and performance on a unit. There is a trade-off among the available
settings. The following description about the settings should help you to
decide which one is suitable to you and your application. You will find further
discussion of this setting in the 3ware Serial ATA RAID Controller User
Guide, under “About StorSave Profile Levels” on page 106.
protect provides the maximum data protection among the controller settings.
When storsave is set to protect mode, it means:
When the unit becomes degraded, the write cache will be disabled.
Write journaling is enabled. All data flushing from controller cache will
be flushed to media.
Incoming FUA (Force Unit Access) host requests will be honored unless
a BBU is installed and enabled, in which case, they will be ignored.
perform provides the maximum performance and least data protection of the
three controller settings. When storsave is set to perform mode, it means:
When the unit becomes degraded, the write cache will not be disabled.
Write journaling is disabled. All data flushing from controller cache will
be flushed to disk. If a BBU is present, this essentially disables the BBU
for this unit.