Enclosure Object Commands
www.3ware.com 97
/cx/ex/pwrs
x
set identify=on|off
This command is used by 9690SA controllers.
This command causes the power supply to be identified by blinking the LED
associated with it, or turns off identification of the LED for this power supply.
Setting identify to on will cause the LED associated with that power supply to
blink.
Example:
//localhost> c0/e0/pwrs1 set identify=on
Sending Identify request to Power Supply c0/e0/pwrs1 to [on] ...
Done.
/c
x
/e
x
/temp
x
show
This command is used by the 9690SA controller.
This command shows the information about the specified temperature sensor
element /fanx in the specified enclosure cx/ex. The possible status values are
OK, OVER-WARNING, OVER-FAIL, UNDER-WARNING, UNDER-FAIL,
where OVER denotes over-temperature and UNDER denotes under-
temperature. For more information about these statuses, see the 3ware Serial
ATA RAID Controller User Guide
Example:
//localhost> /c0/e0/temp0 show
TempSensor Status Temperature Identify
--------------------------------------------------------
temp0 OK 42C(107F) Off
/cx/ex/temp
x
show identify
This command is used by 9690SA controllers.
This command shows the identify status of the specified temp sensor. The
status can be either on or off.
Example:
//localhost> c0/e0/temp1 show identify
c0/e0/temp1 Identify status = on
/cx/ex/temp
x
set identify=on|off
This command is used by 9690SA controllers.
This command causes the temp sensor to be identified by blinking the LED
associated with it, or turns off identification of the LED for this temp sensor.