Controller Object Commands
www.3ware.com 59
having to specify it as a spare. It also means that if you accidentally
disconnect a drive (causing the controller to see it as a failed drive) and then
reconnect it, the controller will automatically try to use it again.
If the policy is off, spares are the only candidates for rebuild operations.
Example:
//localhost> /c0 set autorebuild=enable
Setting Auto-Rebuild Policy on /c0 to enable ... Done.
/cx set autodetect=on|off disk=<p:-p>|all
This command is only for 9000 series controllers.
This command is associated with the staggered spin-up feature when hot-
swapping drives. When staggered spin-up is enabled (see command /cx set
spinup and /cx set stagger), during a reset or power on, the controller will spin
up all detected drives with a delay between each spinup, allowing the spread
of power consumption on the power supply. When a drive is hot-swapped, (as
opposed to when it has just been powered on or reset), the default behavior of
the system is to automatically detect and immediately spin up the drives. This
command can change the default behavior and set the controller to do a
staggered spinup for hot-swapped drives.
autodetect=on|off enables or disables automatic detection of drives on the
controllers ports for staggered spin-up.
disk=<p:-p>|all specifies one or many disks (that is, drives, ports, or vports).
If a port is empty (no drive is inserted), the echo message of the command
refers to a port. If there is already a drive inserted, the message refers to a
disk. The example below shows that autodetect has been set to off to initiate
staggered spin-up during hot-swapping, where port 3 was empty and ports 5
and 6 had drives inserted.
Example:
//localhost>> /c0 set autodetect=off disk=3:5-6
Setting Auto-Detect on /c0 to [off] for port [3] and for disk
[5,6]... Done
If “disk=all,” then all of the drives or ports for that controller are specified.
For the 9690SA controller, it would spinup all directly attached SAS and
SATA drives, but not any drives attached to an expander.
Note: The autodetect setting cannot be shown in CLI or displayed in 3DM or 3BM.
This feature may be added in a future release.