Chapter 2. CLI Syntax Reference
26 3ware Serial ATA RAID Controller User Guide
Note that the device drivers for the appropriate operating system should be
loaded for the list to show all controllers. The intention is to provide a global
view of the environment.
Example for controller without an enclosure and expander:
Typical output of the Show command for a controller looks like the following:
//localhost> show
Ctl Model Ports Drives Units NotOpt RRate VRate BBU
-----------------------------------------------------------------------
c0 9590SE-4ME 4 4 1 0 2 5 -
The output above indicates that Controller 0 is a 9590SE model with 4 Ports,
with 4 Drives detected (attached), total of 1 Unit, with no units in a NotOpt
(Not Optimal) state, RRate (Rebuild Rate) of 2, VRate (Verify Rate) of 5,
BBU of '-' (Not Applicable). Not Optimal refers to any state except OK and
VERIFYING. Other states include VERIFY-PAUSED, INITIALIZING, INIT-
PAUSED, REBUILDING, REBUILD-PAUSED, DEGRADED,
MIGRATING, MIGRATE-PAUSED, RECOVERY, INOPERABLE, and
UNKNOWN. RRate also applies to initializing, migrating, and recovery
background tasks. (Definitions of the unit statuses are available in the 3ware
Serial ATA RAID Controller User Guide.)
Example for 9690SA-414E with enclosure and expander:
Typical output of the Show command for a system with an enclosure,
expander, and a 9690SA-4I4E controller looks like the following:
//localhost> show
Ctl Model (V)Ports Drives Units NotOpt RRate VRate BBU
---------------------------------------------------------------------------
c0 9690SA-4I4E 12 4 1 0 4 4 -
Encl Slots Drives Fans TSUnits PSUnits
---------------------------------------------------
/c0/e0 4 2 1 1 1
show alarms [reverse]
This command shows the alarms or AEN messages of all controllers in the
system. The default is to display the most recent messages at the bottom. The
reverse attribute displays the most recent message at the top.
show diag
This command shows the diagnostic information of all controllers in the
system. The enclosure diagnostic log may be requested by 3ware Customer
Support to help troubleshoot problems on your controller.